Turbidity Meter Specification

  • Frequency
  • 50/60 Hz
  • Interface Type
  • RS232
  • Temperature
  • 0C to 50C
  • Number of Specimens
  • 1
  • Features
  • Auto-ranging, Data hold, Calibratable, Low battery indication
  • Power Supply
  • AC 220V 10%, 50/60 Hz
  • Equipment Type
  • Turbidity Meter
  • Measuring Range
  • 01000 NTU
  • Specimen Size
  • Standard 24 mm vial
  • Application
  • Water turbidity measurement in laboratory and field
  • Humidity
  • 80% RH (non-condensing)
  • Test Range
  • 01000 NTU
  • Automation Grade
  • Manual
  • Response Time
  • <5 seconds
  • Display Type
  • Digital LCD Display
  • Accuracy
  • 2% of reading or 0.01 NTU (whichever is greater)
  • Resolution
  • 0.01 NTU
  • Mounting Type
  • Tabletop
  • Operating Voltage
  • AC 220V
  • Usage
  • Laboratory/Field
  • Machine Weight
  • 1.2 kg
  • Control Mode
  • Manual
  • Battery Backup
  • 6V or 9V rechargeable (optional)
  • Detector
  • Photodiode
  • Enclosure Material
  • ABS Plastic
  • Calibration
  • 1-point, 2-point, or 3-point calibration
  • Storage Conditions
  • -20C to 60C
  • Sample Volume
  • 10 mL minimum
  • Light Source
  • Infrared LED (850 nm)
 
 

Turbidity Meter About



Take advantage of this celebrated Turbidity Meter, designed for accurate water turbidity measurement in both laboratory and field applications. Featuring transcendent precision with a test range of 01000 NTU and lustrous digital LCD display, it offers buy-worthy features like 1-, 2-, or 3-point calibration and auto-ranging. Powered by AC 220V or optional rechargeable battery, this device boasts competitive pricing for unmatched value. Constructed from robust ABS plastic, with an infrared LED light source, its engineered for reliability and effortless data management, complete with RS232 interface.

Turbidity Meter: Usage & Competitive Advantages

Ideal for laboratory and field environments, this Turbidity Meter is widely used for monitoring water quality in research, industrial, and environmental applications. It is used as a primary tool for precise turbidity measurement, ensuring accuracy with features like multi-point calibration and auto-ranging. Its competitive advantages include rapid response time, lustrous digital display, data hold function, robust ABS enclosure, and compatibility with standard 24 mm vials, making it a trusted choice for professionals.


Domestic Market, Shipment, and Supply Details

Serving the domestic market across India, our supply ability ensures consistent product availability. Upon confirmation of your quotation, every Turbidity Meter is carefully dispatched with reliable packaging. Shipment lead times are minimized to facilitate prompt delivery, tailored to meet project timelines. Whether for individual or bulk orders, customers can request quick quotations and expect timely dispatched units, ensuring seamless integration into laboratory or field operations nationwide.


FAQs of Turbidity Meter:


Q: How is the Turbidity Meter calibrated for accurate results?

A: The Turbidity Meter supports 1-point, 2-point, or 3-point calibration for maximized accuracy, allowing users to select the most suitable method based on their testing requirements and standards.

Q: What are the main benefits of using this Turbidity Meter in the field or laboratory?

A: Key benefits include high accuracy (2% of reading or 0.01 NTU), rapid response time, a digital LCD display for easy readings, auto-ranging capability, and the flexibility of both mains and rechargeable battery operation.

Q: Where can this Turbidity Meter be used effectively?

A: This meter is designed for both laboratory and field environments, making it ideal for water treatment plants, environmental monitoring stations, and academic research settings throughout India.

Q: What is the process for obtaining a quotation or placing an order?

A: Customers can request a quotation by contacting the manufacturer or supplier directly. Once the quotation is accepted, your order will be processed efficiently and the product will be dispatched as per the agreed timelines.

Q: How does the Turbidity Meter handle low battery situations?

A: The device features a low battery indication to alert users, and it supports an optional rechargeable battery backup, ensuring uninterrupted testing even in remote settings.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Analytical Equipment Category

Digital Photo Calori Meter

Digital Photo Calori Meter

Features : Auto zero, Stable digital display, Light weight, Rugged construction

Usage : Laboratory

Interface Type : Manual

Application : Calorific Value Determination

Measuring Range : 09999 Calories

Response Time : Instant

Electronic Water Soil Analyser Kit

Electronic Water Soil Analyser Kit

Features : Portable, multiparameter, rugged design, infield operation, quick measurement

Usage : Laboratory/Field Testing

Interface Type : Touch keys, LCD display

Application : Measurement of soil and water parameters (pH, EC, TDS, temperature)

Measuring Range : pH: 310, EC: 020 mS/cm, TDS: 01999 ppm, Temperature: 0C50C

Response Time : <10 seconds

Bomb Calorimeter Digital & Microprocessor (with Safety Device)

Bomb Calorimeter Digital & Microprocessor (with Safety Device)

Features : Safety Device, Auto Calibration, Data Storage

Usage : Laboratory Analysis

Interface Type : USB/RS232 Compatible

Application : Gross calorific value determination of solids/liquids

Measuring Range : 0 10,000 Cal/g

Response Time : Instantaneous (Microprocessor) to <2 sec

Auto Karl Fischer Titri Meter

Auto Karl Fischer Titri Meter

Features : Auto Titration, Drift Correction, End Point Indication, LED Stirring

Usage : Laboratory Water Determination

Interface Type : RS232/USB (Depending on model)

Application : Measurement of water content in various substances

Measuring Range : 10 g to 500 mg HO

Response Time : Immediate (Typically < 5 seconds for endpoint detection)



Correspondence Address
C-241, Jhilmil Colony, Delhi - 110095